The battery health subsystem records every battery sample, classifies charge sessions, computes per-job drain rates, and surfaces twelve sensors plus a Metrics sub-tab. This document covers the math, the zone-definition rationale, the per-bucket aggregation rules, and how to use the data in automations.

For the user-facing tour see user-guide/13-battery-health.md. For internal architecture see dev/12-battery-system.md.


Cycle counting

The integration uses the industry-standard cumulative drain รท 100 definition:

cycles = cumulative_drain_pct / 100

Every percent the battery drops is added to a running counter, regardless of whether you charge it back up. After 100 percentage points of drain (which can take many partial discharges), one full cycle has been logged. Charging never decrements the counter โ€” only drain wears the cell.

The counter:

  • Persists across HA restarts. Stored in eufy_vacuum.storage.
  • Is monotonic. Never decreases, never resets โ€” match it against manufacturer cycle ratings (~1000 cycles for typical Li-ion robots) to estimate remaining service life.
  • Ignores implausibly fast per-sample changes. If a single sample reports a delta of more than 3 percentage points (MAX_DELTA_PCT), the whole delta is discarded. Real per-sample motion tops out around ยฑ2-3 pp on ~30 s sample intervals; anything bigger is almost always a firmware Xโ†’0 / 0โ†’X flip, an HA restart gap, or multi-hour self-discharge being booked as a single observation. Without this guard, those events would silently inflate the cycles counter by tens of percentage points each time HA missed events. Rejected deltas are preserved in samples.jsonl as rejected_delta_pct for audit (see Raw data files below).

Charge zones

Li-ion charge curves have three distinct phases. Two of them are diagnostic; one isn't. The integration tracks each.

Low zone โ€” battery โ‰ค 29 %

Slow start of the charge curve. If the cell was deeply discharged the charger uses a precharge / lower-CC current to safely revive the cell, transitioning to full constant-current at around 25-30 %. Slow rebound from low SoC suggests cell chemistry issues โ€” soft shorts, electrolyte degradation. Less commonly the leading degradation indicator, but catches failure modes the high-zone metric misses.

The integration updates sensor.<vacuum>_charge_rate_low_zone only when battery is in this range.

Mid zone โ€” 29-80 %

Constant-current phase. Maximum charge rate; battery accepts current at full speed. Charge rate here is dominated by the charger and thermal headroom, not the battery's condition. Mixing this zone into the average dilutes the diagnostic signal โ€” that's exactly why the integration tracks zones separately rather than reporting a single "average rate".

This zone has no dedicated sensor. It does feed sensor.<vacuum>_charge_rate (the overall instantaneous rate), but most of that sensor's variance comes from the slow zones.

High zone โ€” battery โ‰ฅ 80 %

Constant-voltage phase ("CV taper"). Voltage is held at maximum while current decays. As cells age, internal resistance rises and the charger has to taper sooner and slower โ€” so this region stretches noticeably long before nominal capacity loss shows up. The earliest early-warning signal.

The integration updates sensor.<vacuum>_charge_rate_high_zone only when battery is in this range.

Mid-job recharge โ€” 15โ†’75 %

Not a zone of the charge curve but a type of session. When the X10 Pro Omni runs a multi-room job and battery drops to ~15 %, it returns to the dock for a partial recharge to ~75 %, then resumes. Other Eufy models use similar logic.

Mid-job recharges are gold-standard diagnostic data:

  • Tight, repeatable window โ€” same start/end SoC every time.
  • Pure constant-current region โ€” no precharge slowness, no CV taper variance.
  • Consistent thermal load โ€” vacuum is hot from cleaning every time.
  • Frequent โ€” every multi-room job that exceeds ~85 % drain triggers one.

sensor.<vacuum>_mid_job_recharge_rate exposes a rolling mean of these sessions' average rates. A drop of 5-10 % in this metric over months is a more reliable health signal than the headline _battery_health percentage.


Health proxy

The integration tracks battery aging as two separate regime indices plus a headline alias. Both indices compare current charge speed to a per-install baseline anchored on the first qualifying recharge the integration observes.

Why per-install, not factory-fresh?

The integration has no way to estimate factory-fresh charge performance for your specific battery. Cell chemistry varies by manufacturing lot; ambient temperature, charger hardware, dock contact resistance, and the firmware's CV-taper aggressiveness all shift the curve in ways software can't introspect. Pretending to know what "100 % healthy" looks like for your battery would be guessing.

Instead, the baseline is "your battery, the first time we measured it." Health % becomes "how does today compare to back then" โ€” the comparison the user actually cares about, computed from data the integration actually has. A side benefit: the same baseline mechanism trivially handles battery replacement (call the rebaseline service, next qualifying recharge re-anchors).

Why two regimes?

A Li-ion charge curve from โ‰ค 50 % to โ‰ฅ 90 % crosses two physically distinct regions that age in opposite directions:

Regime Range Dominant phase Aging signal
CC 50โ†’80 % Constant-current bulk charging Capacity loss โ†’ aged cells hold less energy per percent โ†’ %/min appears faster
CV 80โ†’90 % Constant-voltage taper Resistance rise โ†’ aged cells force earlier/longer taper โ†’ %/min appears slower

Averaging the two into one session-wide rate (the previous design) cancels real signal โ€” a battery that's lost capacity AND gained resistance can show a flat health % even as both effects worsen. The fix is to track each regime independently against its own anchor.

The integration exposes both:

  • sensor.<vacuum>_cc_charge_speed โ€” capacity proxy (CC regime). Drops as the cell loses usable capacity.
  • sensor.<vacuum>_cv_charge_speed โ€” resistance proxy (CV regime). Drops as internal resistance rises.
  • sensor.<vacuum>_battery_health โ€” headline. Alias of cv_charge_speed. Kept under this entity_id for continuity with installs that pre-date the regime split, since CV-side slowdown is what most users mean by "battery health".

Both regime sensors use the same scale: 100 % matches your install baseline, below 100 % is slower than baseline, above 100 % is faster (rare but not a malfunction).

Baseline

A "qualifying recharge" is a session where:

  • start_battery โ‰ค 50 % (HEALTH_QUALIFY_START_MAX)
  • end_battery โ‰ฅ 90 % (HEALTH_QUALIFY_END_MIN)

The baseline is anchored on the first qualifying session that has both regimes populated (BASELINE_SAMPLE_COUNT = 1). The baseline storage block carries one anchor value per regime, plus shared metadata:

"baseline": {
    "cc_min_per_pct": 0.85,               # CC anchor rate (50โ†’80 minutes/percent)
    "cv_min_per_pct": 4.20,               # CV anchor rate (80โ†’90 minutes/percent)
    "session_count": 1,                   # always 1 with the per-install model
    "anchored_at": "2026-05-08T19:42Z",   # the seed session's end_ts, for audit
}

Until the baseline is anchored, both regime sensors and the headline return None and the at-a-glance chip in the card shows "Building baseline". A session that qualifies on overall window (50โ†’90) but only crosses one regime (e.g. 51โ†’89, which has no CV span) does not anchor the baseline โ€” the integration waits for a session that crosses both, so both anchors come from the same physical recharge.

Why 50โ†’90, not the textbook 30โ†’95? A robot vacuum on single-room jobs rarely drains far enough for the strict window to fire. The 30โ†’95 window left baselines unseeded for months on real installs. The 50โ†’90 window covers both the CC region (50โ†’80) and the CV taper (80โ†’90), so a single qualifying recharge populates both regime anchors at once.

Why anchor on one session? The baseline isn't trying to estimate a population mean of "factory-fresh charge speed" โ€” that would need a large sample. It's just recording "the rate this battery charged at when measurement began." One session is all that requires. Variance in the seed translates 1:1 into variance in future readings, but since the user observes trend over months โ€” not the absolute number โ€” that variance is irrelevant to the question being answered. The 14-day rolling current window smooths comparison-side noise.

Per-regime accumulation

While charging, every sample interval that gains percentage is split linearly across the CC/CV boundary. A sample that crosses 78 โ†’ 82 (raw_delta = 4 over, say, 8 minutes) attributes 2 pp + 4 minutes to CC and 2 pp + 4 minutes to CV. The accumulators live on current_session.cc_duration_min, cc_delta_pct, cv_duration_min, cv_delta_pct and roll into the closed session's summary as cc_min_per_pct / cv_min_per_pct for use by _update_health.

The same constant-rate-within-a-sample assumption that rate_per_min makes is used for the split โ€” the per-sample interval is short enough (typically 30 s with the eufy-clean integration) that the constant-rate approximation is reasonable.

Current

A 14-day (CURRENT_WINDOW_DAYS) rolling window of qualifying sessions. If no sessions fall in the window, the most recent qualifying session is used as a fallback so the sensor never gets stuck at None after baseline is set.

The 14-day window (vs. the more conventional 7) is sized to match real-world recharge frequency: a vacuum running mostly single-room jobs may go several days between sessions that hit even the relaxed 50โ†’90 window. A 7-day window risked spending most of its time on the fallback (= comparing baseline to a single recent session); 14 days reliably has multiple samples to average over.

Forcing a baseline

To anchor the baseline immediately rather than waiting for organic use, run one heavy-load job. The recipe maximises wattage so the cell drains to โ‰ค 50 % in a single job:

  • As many rooms as you can queue โ€” full house is ideal, but more is more whatever the count.
  • Max suction (turbo / max).
  • Max water level if mopping โ€” pad drag at high water pressure is the biggest single power draw.
  • Narrow path or 2 passes โ€” doubles minutes-per-mยฒ.
  • Edge cleaning on โ€” adds a perimeter pass.

After the job, dock for an uninterrupted charge to โ‰ฅ 90 %. On session-close, _update_health sees one qualifying session in session_history_recent with both regimes populated and anchors baseline.cc_min_per_pct, baseline.cv_min_per_pct, baseline.session_count = 1, baseline.anchored_at = end_ts in one shot.

Don't try to bleed the battery down by leaving the vacuum off the dock idle โ€” standby draw is too low to hit 50 % in any reasonable time. The high-power cleaning configuration is the only practical way to force a deep cycle.

Best done within the first week or two post-install while the battery is healthy โ€” the baseline anchors whatever charge rate the battery has at the time, so anchoring on a degraded battery means future health % readings will be flat 100 % despite ongoing aging.

Re-baselining

After a battery replacement, the existing baseline is wrong (it describes the old cell) and health % becomes meaningless. Call the service:

service: eufy_vacuum.battery_rebaseline
data:
  vacuum_entity_id: vacuum.alfred

This sets baseline.cc_min_per_pct, baseline.cv_min_per_pct, baseline.session_count, baseline.anchored_at, and all three stat fields (stats.cc_charge_speed_pct, stats.cv_charge_speed_pct, stats.health_pct) to None. The next qualifying recharge re-anchors all of them in one go. Cycles, cumulative drain, per-job aggregates, mid-job rate, and session history are not touched โ€” those still reflect the vacuum's lifetime telemetry, which doesn't reset on a battery swap.

Formula

Both regime indices use the same shape, just different baseline + current values:

cc_charge_speed_pct = round(baseline.cc_min_per_pct / current_cc_min_per_pct * 100, 1)
cv_charge_speed_pct = round(baseline.cv_min_per_pct / current_cv_min_per_pct * 100, 1)
health_pct          = cv_charge_speed_pct   # alias

Where current_<regime>_min_per_pct is the mean of that regime's min_per_pct across qualifying sessions whose end_ts falls within CURRENT_WINDOW_DAYS (14). Falls back to the most recent qualifying session that has the regime populated when the rolling window is empty.

Interpretation (assuming the baseline was anchored when the battery was healthy):

Range Meaning (applies to both CC and CV)
95-105 % Matches your install baseline. Normal noise.
85-95 % Slower than baseline. Could be environmental drift or early aging โ€” track the trend.
70-85 % Substantially slower than baseline. Meaningful drift in this regime.
< 70 % End-of-life relative to your baseline for this regime.
Above 105 % Briefly possible โ€” cooler ambient, looser charge cycle, or noise on a small dataset. Not a malfunction.

A drop in both CC and CV over the same horizon is the strongest replacement signal โ€” capacity loss and resistance rise both worsening together is the textbook end-of-life profile. A drop in only one warrants more data before acting; environmental drift can move either independently for weeks.

The thresholds assume a healthy-battery anchor. If the install baseline was seeded on an already-worn battery (e.g. integration installed years into the vacuum's life), the percentages don't map to absolute battery condition โ€” only to drift since seeding. A flat 100 % from such a baseline doesn't mean "healthy", just "unchanged from when measurement started." This is why anchored_at is recorded: knowing when the baseline was seeded contextualises today's reading.

Important caveats

  • The vacuum reports SoC %, not actual current/voltage. What we measure is observed minutes per percent. That conflates battery condition + charger behaviour + ambient temperature. Indoor use stabilises temperature; the charger is fixed; so what's left is the battery โ€” but the metric isn't direct capacity.
  • Don't over-react to a single bad week. Trends matter more than instantaneous values. Same-season comparisons across months are diagnostic; month-to-month within a year is noise.
  • CC and CV move independently. They're measuring different physical effects (capacity vs resistance) with different ambient sensitivities. A divergence between them โ€” CV stable while CC drops sharply, or vice versa โ€” is informative on its own and shouldn't be dismissed as noise.
  • The mid-job recharge rate is a useful third opinion. Different methodology (rolling mean rather than baseline-relative) so the metric drifts independently. A drop alongside the regime sensors is corroboration.
  • Health % is intentionally relative, not absolute. It tells you "is this battery still doing what it was doing when you started measuring it." That's the question the integration can actually answer. Absolute statements like "this battery is at 80 % of factory capacity" require lab equipment or manufacturer telemetry the vacuum doesn't expose.

Per-job battery_metrics

Every completed cleaning job gets a battery_metrics block attached to its job record (in addition to the existing job-finalizer fields). The block covers job-level drain rates and an attempt at per-mode/suction/water attribution.

Schema

{
    "battery_used_pct": 12,                  # battery_start - battery_end
    "duration_min": 30.2,                    # wall-clock minus pauses + recharges
    "area_m2": 65.5,                         # from sensor.<vacuum>_cleaning_area
    "drain_per_min": 0.397,
    "drain_per_hour": 23.84,
    "drain_per_m2": 0.183,

    "is_single_clean_mode": True,            # eligible for per-mode aggregate
    "is_single_fan_speed": True,
    "is_single_water_level": True,
    "mid_job_recharge": False,               # added by job_finalizer (not compute); a flagged
                                             # run is kept OUT of the per-config drain buckets
    "single_clean_mode": "vacuum_mop",       # set when is_single_*
    "single_fan_speed": "max",
    "single_water_level": "off",

    "by_clean_mode":   {"vacuum_mop": {"area_m2": 65.5, "share": 1.0, "rooms": 4}},
    "by_fan_speed":    {...},
    "by_water_level":  {...},

    "passes_share":    {"1": 0.65, "2": 0.35},
    "edge_mopping":    {"on_share": 0.32, "off_share": 0.68},

    "weighted_by":     "estimated_minutes" | "room_count" | "none",
}

Weighting

Per-room mยฒ is not reported by the device โ€” only the job-wide total. To produce per-bucket area shares, the integration prorates total mยฒ across rooms by estimated_minutes from the learning system's per-room enrichment. So if the job's 65.5 mยฒ had 10 min vacuum_mop and 5 min vacuum (estimated), the vacuum_mop bucket gets 0.667 share = 43.7 mยฒ.

When estimates aren't available (e.g. learning hasn't seen those rooms enough), the fallback is equal-weight per room. Either way the per-bucket area shares sum to the job total.

Single-bucket gating โ€” the most important rule

Per-bucket drain attribution is only honest for jobs where every room used the same setting for that key. A mixed-mode run can't tell you "mop mode used X %/mยฒ and vacuum mode used Y %/mยฒ" because the vacuum doesn't report per-room battery telemetry.

The integration handles this with single-bucket gating:

  • Mixed-mode runs feed only the All jobs running mean.
  • Single-bucket runs (every room same clean_mode, or same fan_speed, or same water_level) feed both All jobs and the matching per-bucket mean.

This is the same single-room-jobs-are-king philosophy the learning system uses for per-room timing. Keeps aggregates unbiased; mixed runs still get full job-level stats.

Post-job recharge linkage

When record_job_metrics fires, the next charge session within 4 hours is linked to that job's record as last_job.post_job_charge. The block includes the recharge's start/end battery, duration, average rate, and ended_reason. This gives you a "this job used 25 % battery โ†’ the recharge that followed took 73 minutes 60โ†’100 %" pairing โ€” the ground-truth recovery curve, useful for spotting jobs that disproportionately stress the battery.

If the vacuum doesn't dock for a full charge within 4 hours (e.g. you pull it off mid-recharge), the linkage is dropped to avoid false attribution.


Sensors reference

All twelve sensors are pre-fixed with the vacuum's object_id (e.g. sensor.alfred_charge_cycles for vacuum.alfred).

Sensor suffix State Unit Attributes
_charge_cycles cumulative cycles (count) cumulative_drain_pct, completed_sessions
_charge_rate last instantaneous rate %/min battery_level, charging, last_sample_ts
_charge_rate_low_zone last rate when โ‰ค 29 % %/min as above
_charge_rate_high_zone last rate when โ‰ฅ 80 % %/min as above
_mid_job_recharge_rate rolling mean of mid-job rates %/min sample_count, last_rate_per_min, last_recorded_at
_last_charge_duration minutes for last completed session min last_charge_delta_pct
_battery_health headline; alias of _cv_charge_speed % baseline_cv_min_per_pct, baseline_cc_min_per_pct, baseline_session_count, baseline_anchored_at, completed_sessions
_cc_charge_speed CC regime (50โ†’80) speed vs baseline % baseline_min_per_pct, baseline_session_count, baseline_anchored_at
_cv_charge_speed CV regime (80โ†’90) speed vs baseline % baseline_min_per_pct, baseline_session_count, baseline_anchored_at
_last_job_drain_per_min drain rate of last job %/min (see below)
_last_job_drain_per_hour scaled to hours %/h (see below)
_last_job_drain_per_m2 drain per mยฒ of last job %/mยฒ (see below)

The _cc_charge_speed / _cv_charge_speed attribute named baseline_min_per_pct carries that regime's anchor (i.e. CC's anchor on the CC sensor, CV's on the CV sensor). The headline _battery_health sensor surfaces both anchors plus baseline_anchored_at for audit.

Legacy entity ID note: Installs registered before the entity ID pinning fix may have sensor.<vacuum>_last_job_drain_rate instead of sensor.<vacuum>_last_job_drain_per_min โ€” this is the same sensor under an older label-derived name. Both forms are supported by the panel card. New installs and freshly-deleted-and-recreated registry entries will use the _per_min form. To migrate an existing install: delete the entity from Settings โ†’ Devices & Services โ†’ Eufy Vacuum โ†’ Entities and reload the integration; it'll re-register at the new name.

Last-job sensor attributes

The three _last_job_* sensors carry the same rich attribute payload, including:

  • job_id, recorded_at, duration_min, area_m2, battery_used_pct
  • single_clean_mode, single_fan_speed, single_water_level โ€” null when mixed
  • mid_job_recharge โ€” True if the run recharged mid-clean (excluded from the per-config drain means)
  • weighted_by โ€” how per-room weights were computed
  • post_job_charge โ€” the linked recharge session (null if not yet observed)
  • all_jobs_mean, all_jobs_count โ€” running mean across all jobs
  • by_clean_mode_mean, by_fan_speed_mean, by_water_level_mean โ€” per-bucket means and counts (only fed by single-bucket jobs)

Raw data files

Two append-only files per vacuum, written under:

config/eufy_vacuum/battery/<object_id>/

samples.jsonl

One JSON object per line, written on every observation โ€” accepted and rejected. Accepted samples have delta_pct populated and rejected_delta_pct null; rejected samples are the inverse:

{"ts": "2026-05-08T12:34:56+00:00", "battery_level": 82, "charging": true,  "delta_pct": 1.0,   "rate_per_min": 0.5, "zone": "high", "drain_added": 0.0, "cycles": 12.34, "rejected_delta_pct": null}
{"ts": "2026-05-08T13:01:09+00:00", "battery_level": 0,  "charging": false, "delta_pct": null,  "rate_per_min": null,"zone": "low",  "drain_added": 0.0, "cycles": 12.34, "rejected_delta_pct": -82.0}

rejected_delta_pct is non-null only when the MAX_DELTA_PCT guard fired (see Cycle counting). It carries the rejected raw delta magnitude so post-hoc analysis can see the size of every flip the integration filtered out:

# Find every rejection event in the log:
grep '"rejected_delta_pct": [^n]' samples.jsonl

# Histogram of rejection magnitudes (requires jq):
jq -r 'select(.rejected_delta_pct != null) | .rejected_delta_pct' samples.jsonl | sort -n | uniq -c

A noisy install (lots of rejections) is a signal that either the upstream firmware is misbehaving or HA is restarting frequently; either way the cycles counter stays accurate because the guard protects it.

Use tail -f or jq for live monitoring; rotate or archive periodically since the file grows forever.

sessions.csv

One row per completed charge session, header on first write:

start_ts,end_ts,duration_min,start_battery,end_battery,delta_pct,avg_rate_per_min,min_rate_per_min,max_rate_per_min,samples,ended_reason

ended_reason is full (battery hit 100 %) or stopped (charging ended early). Open in any spreadsheet for trend charting.


Automation examples

Notify on health drop

automation:
  - alias: Battery slower than install baseline
    trigger:
      - platform: numeric_state
        entity_id: sensor.alfred_battery_health
        below: 80
        for: "01:00:00"   # debounce against noise
    action:
      - service: notify.mobile_app_phone
        data:
          title: "Vacuum charging slower than baseline"
          message: >
            Charge speed is now {{ states('sensor.alfred_battery_health') }}% of the install
            baseline. Battery is meaningfully aged compared to when measurement started.

Rebaseline after battery replacement

Either call the service directly:

service: eufy_vacuum.battery_rebaseline
data:
  vacuum_entity_id: vacuum.alfred

Or wire it into your battery-replacement workflow โ€” for example, an input boolean toggle that resets the baseline and notifies:

automation:
  - alias: Rebaseline vacuum battery
    trigger:
      - platform: state
        entity_id: input_boolean.alfred_battery_replaced
        to: "on"
    action:
      - service: eufy_vacuum.battery_rebaseline
        data:
          vacuum_entity_id: vacuum.alfred
      - service: input_boolean.turn_off
        target:
          entity_id: input_boolean.alfred_battery_replaced
      - service: notify.mobile_app_phone
        data:
          title: "Battery baseline cleared"
          message: >
            Run one heavy job (max suction, max water, all rooms) and let the vacuum
            recharge. The next qualifying recharge will anchor the new baseline.

Track cycles for replacement planning

template:
  - sensor:
      - name: "Alfred battery cycles remaining"
        unit_of_measurement: "cycles"
        state: >
          {{ 1000 - (states('sensor.alfred_charge_cycles') | float(0)) | round(0) }}
        attributes:
          replacement_due_at: >
            {{ ((1000 - (states('sensor.alfred_charge_cycles') | float(0))) /
                ((states('sensor.alfred_charge_cycles') | float(0)) /
                 ((as_timestamp(now()) - as_timestamp('2026-01-01')) / 86400 / 365))) | round(1) }} years

Skip cleaning if battery health critically low

automation:
  - alias: Pause schedule if battery is dying
    trigger:
      - platform: numeric_state
        entity_id: sensor.alfred_battery_health
        below: 65
    action:
      - service: switch.turn_off
        target:
          entity_id: switch.daily_vacuum_schedule
      - service: notify.mobile_app_phone
        data:
          title: "Vacuum schedule paused"
          message: >
            Battery health dropped below 65%. Daily schedule disabled โ€”
            jobs may not complete reliably until the battery is replaced.

Compare per-mode efficiency

The per-mode means are exposed as attributes on sensor.alfred_last_job_drain_per_m2:

template:
  - sensor:
      - name: "Mop drain per m2"
        state: >
          {{ state_attr('sensor.alfred_last_job_drain_per_m2', 'by_clean_mode_mean')
             .get('vacuum_mop', {}).get('mean', 0) | round(3) }}
        unit_of_measurement: "%/mยฒ"

      - name: "Vacuum drain per m2"
        state: >
          {{ state_attr('sensor.alfred_last_job_drain_per_m2', 'by_clean_mode_mean')
             .get('vacuum', {}).get('mean', 0) | round(3) }}
        unit_of_measurement: "%/mยฒ"

Compare these two over a few weeks to see how much extra battery your mop runs cost.


Charting

Recommended approach: live sensors โ†’ HA's history-graph or apexcharts-card. Long-term trends โ†’ CSV in a spreadsheet.

# Health trend chart โ€” drop into a dashboard card
type: history-graph
title: Battery health (90 days)
hours_to_show: 2160
entities:
  - sensor.alfred_battery_health        # headline (= CV regime)
  - sensor.alfred_cc_charge_speed       # CC regime (capacity proxy)
  - sensor.alfred_mid_job_recharge_rate
  - sensor.alfred_charge_rate_high_zone

For per-mode bar charts and grouped time series, apexcharts-card handles attribute access and grouping cleanly.