Battery Subsystem — Accounting Follow-ups

Two tracked items surfaced 2026-06-20 while reviewing battery/ against a mid-job recharge run (an external Vac+Mop clean that returned to dock at 9% and recharged). Neither is a bug in the real-time session engine — cycle counting, charge-session tracking, the CC/CV regime split, the per-install health proxy, and the gold-standard mid_job_recharge_stats all handle a recharge correctly. Both items are about the per-job drain metric (battery/job_metrics.py → fed by learning/job_finalizer.py).

Context: the session engine (battery/manager.py, BatteryHealthManager) watches the battery sensor and is job-type-agnostic, so charge/cycle/health data is captured for any run. The per-job drain metric is a separate, dispatched-run-only path — that's where both gaps live.


Item 1 — per-job drain is recharge-naive (biases dispatched recharge runs low)

✅ FIXED 2026-06-20 (option a). A mid-job-recharge run is flagged in job_finalizer (battery_metrics["mid_job_recharge"], from the active job's recharge_seconds_accumulated / observed_mid_job_recharge_count), and record_job_metrics keeps a flagged run OUT of the per-config drain buckets (by_clean_mode / by_fan_speed / by_water_level) — the same anti-bias spirit as the is_single_* gates. It still records last_job (with the flag) and all_jobs. Option (b) — true discharge from the session engine's cumulative_drain_pct — remains the richer future fix if recharge runs become common.

⚠ Blind spot re-opened by native charge steps (unreleased, post-v1.6.7). The mid_job_recharge gate keys ONLY on the UNPLANNED-recharge counters (recharge_seconds_accumulated / observed_mid_job_recharge_count), which are set from _is_low_battery_return_state — a deep-low return the robot took on its own. A native charge_wait step (jobs/phase_runner.py:_run_charge_wait_phase, dock → poll to target_battery_percent → advance) is a DELIBERATE mid-job recharge, and active_job.py:update_active_job_recharge_observation deliberately early-returns for a charge_wait phase so the commanded dock is NOT double-counted as a battery-driven recharge — so neither counter increments and mid_job_recharge stays False. A single-setting stepped run with a charge step therefore nets its intentional recharge out of start − end and re-injects the understated drain Item 1 exists to block. Fix later by ALSO flagging a run whose active_job['phases'] contains a charge_wait phase (or by adopting option (b), whose cumulative_drain_pct delta is recharge-agnostic and covers both pathways). The charge_wait phase does track its own charge_from_battery / charge_to_battery edges, so the true discharge across the step is still reconstructable.

Where: learning/job_finalizer.py:791 calls compute_job_battery_metrics(battery_start=…, battery_end=…) with the raw job-edge battery levels. battery/job_metrics.py:_safe_drain computes drain = start − end.

Symptom: on a job with a mid-job recharge, start − end nets out the recharge, so battery_used_pct, drain_per_min, drain_per_hour, and drain_per_m2 understate the true discharge. Example: 100 → 9 (drained 91), recharge to 80, finish at 50 → reported drain 50, true discharge ≈ 121.

Why it matters: BatteryHealthManager.record_job_metrics feeds single-bucket jobs (is_single_clean_mode/fan_speed/water_level) into the by_clean_mode / by_fan_speed / by_water_level drain aggregates, with no mid_job_recharge gate. A single-setting recharge run (e.g. Vac+Mop / Turbo / Low water) therefore injects an understated drain into those per-config means and biases them low. Note the asymmetry: duration IS recharge-adjusted (recharge seconds are booked as overhead, job_finalizer.py ~line 502), but drain is not — so drain_per_min is wrong in both numerator and denominator-relative terms.

Fix options: - (a) Gate it out (simplest, mirrors the existing anti-bias design). When the job had a mid-job recharge (battery.mid_job_recharge_observed / recharge_seconds_accumulated > 0), exclude it from the per-job drain aggregates — same spirit as the is_single_* gates that already keep mixed-mode jobs out of per-bucket drain. The job still records last_job; it just doesn't pollute the means. - (b) Compute true drain (more complete). Source the per-job discharge from the session engine's cumulative_drain_pct delta over the job window — it already sums only drops across the recharge, so it's the true discharge by construction. Then the aggregate is both correct AND keeps the recharge run as a data point.

Recommendation: (a) now (cheap, honest), (b) later if recharge runs become common enough that dropping them loses meaningful coverage.


Item 2 — external (app-started) runs compute no per-job battery metrics

Where: learning/external_ingest.py has zero battery references; build_graduated_job emits no battery / battery_metrics block.

Symptom: drain_per_m2 and the per-config drain aggregates only ever build from dispatched (integration-started) runs. An app-started clean contributes nothing to the per-job drain picture — so tonight's external run produces no per-job drain number at all.

Why it matters: if most cleans are app-started, the per-config drain aggregates stay sparse / slow to converge. (The charge/cycle/health side is unaffected — the session engine captures it regardless of job type, and the raw per-sample JSONL has the full discharge curve, so the true discharge rate is always recoverable from the archive.)

Likely intentional, but worth a decision: external runs lack a reliable dispatched battery_start / battery_end capture. Options: - Capture battery_start / battery_end for external runs from the recorder battery timeline at the run-window edges (and fold in recharge per Item 1) so external runs feed the same per-config aggregates. - Or explicitly document that per-job battery drain is a dispatched-run-only metric, and point users at the raw battery JSONL / session stats for external-run battery insight.


Not affected (captured correctly regardless)

  • Cycle countercumulative_drain_pct sums only drops; charging never decrements.
  • Charge-rate / zone / CC-CV / health — driven by the battery sensor via charge sessions.
  • mid_job_recharge_stats — a mid-job recharge from a deep low is the engine's gold-standard signal; a 9 → ≥90 recharge also spans both CC and CV, so it can seed/refresh the per-install health baseline.
  • Raw archivebattery/store.py writes a per-sample JSONL + sessions.csv, so the true discharge (e.g. 100 → 9) and the charge curve are always reconstructable post-hoc.